Imodyuli ye-SPO2 yokujonga ukusebenza okuphezulu kwezonyango enezinga lokuphefumla le-RR
Iimpawu zeMveliso
UHLOBO | Ibhodi ye-SPO2 yokuhlola ukusebenza okuphezulu kwezonyango |
Udidi | Ibhodi ye-SPO2\Imodyuli yeoksijini yegazi\SPO2 imodyuli |
Uthotho | narigmed® NOMZ -GH |
Bonisa ipharamitha | SPO2\PR\PI\RR |
Uluhlu lomlinganiselo we-SpO2 | 35%~100% |
SpO2 umlinganiselo Ukuchaneka | ±2% (70% ~100%) |
Umlinganiselo wesisombululo se-SpO2 | 1% |
Uluhlu lomlinganiselo wePR | 25 ~ 250bpm |
Umlinganiselo wePR Ukuchaneka | Ubukhulu be ±2bpm kunye±2% |
Umlinganiselo wesisombululo sePR | 1bpm |
Ukusebenza kwe-Anti-motion | SpO2±3% I-PR ± 4bpm |
Ukusebenza kwe-perfusion ephantsi | SPO2 ±2%, PR ±2bpm Inokuba ngaphantsi njenge-PI=0.025% kunye ne-Narigmed's probe |
perfusion Index Range | 0%~20% |
PI isisombululo ratio | 0.01% |
Izinga lokuphefumla | 4rpm ~70rpm |
Umlinganiselo wesisombululo seRR | 1rpm |
Imifanekiso yePlethyamo | Umzobo webar\Pulse wave |
Ukusetyenziswa kwamandla okuqhelekileyo | <15mA |
Cwangcisa ukubhaqwa\Cwangcisa ukufunyaniswa kokusilela | EWE |
Ukunikezwa Amandla | 5V DC |
Ixesha lemveliso yexabiso | 4S |
Indlela yonxibelelwano | Unxibelelwano lwe-TTL lwe-serial |
Inkqubo yonxibelelwano | inokwenzeka |
Ubungakanani | 51mm*35mm*6.3mm |
Iindlela zocingo | Uhlobo lwesokethi |
Isicelo | Ingasetyenziswa kwimonitha |
Ubushushu bokusebenza | 0°C ~ 40°C 15%~95%( ukufuma) 50kPa ~ 107.4kPa |
indawo yokugcina | -20°C ~ 60°C 15%~95%( ukufuma) 50kPa ~ 107.4kPa |
Iimpawu ezilandelayo
1. Umlinganiselo wexesha langempela le-pulse oxygen saturation (SpO2)
2. Ukulinganisa izinga le-pulse (PR) ngexesha langempela
3. Umlinganiselo wexesha langempela lesalathisi se-perfusion (PI)
4. Ukulinganisa izinga lokuphefumula (RR) ngexesha langempela
5. Ukukwazi ukuxhathisa ukuphazamiseka kwentshukumo kunye nomlinganiselo obuthathaka we-perfusion. phantsi kokunyakaza okungahleliwe okanye rhoqo kwi-0-4Hz, i-0-3cm, ukuchaneka kwe-pulse oximetry (SpO2) yi-± 3%, kwaye ukuchaneka komlinganiselo wesantya se-pulse ± 4bpm. Xa isalathisi esisezantsi se-perfusion sikhulu okanye silingana ne-0.025%, ukuchaneka kwe-pulse oximetry (SpO2) yi-± 2%, kwaye ukuchaneka komlinganiselo wesantya se-pulse yi-± 2bpm.
Ingcaciso emfutshane
Kungakhathaliseki ukuba xa ulinganisa iinxalenye ze-perfusion ezibuthathaka, inkqubo inokubonelela ngohlalutyo oluchanekileyo lwedatha kwaye inokuvelisa ngokukhawuleza nangokuchanekileyo amaxabiso. Iingenelo eziphambili zale nkqubo zibandakanya: ukulinganisa okuphezulu kweparameter ye-physiological, i-multi-functional physiological parameter monitoring, ukubonwa kwedatha, ukuzinza kunye nokhuseleko kunye nokuthembeka. Ngokukodwa, inkqubo isebenzisa i-algorithms ye-software yobunini kunye ne-probes probes ukulinganisa ngokuchanekileyo iiparamitha ze-physiological ezifana nobushushu bomzimba kunye nesantya sokuphefumula kwezilwanyana kunye nokubonelela ngohlalutyo oluchanekileyo lwedatha. Inkqubo isebenzisa indlela yokulinganisa i-non-invasive, engenabuhlungu engabangeli nayiphi na ingozi kwisilwanyana kwaye ineempawu zokuthintela ukulahleka kwedatha kunye nokukhusela ubumfihlo. Isishwankathelo, itekhnoloji kaNarigmed inethemba elibanzi losetyenziso kunye nexabiso lentengiso, kwaye inokubonelela ngenkxaso yedatha ethembekileyo kuphononongo lweempawu zomzimba wezilwanyana kunye nokuxilongwa kwezonyango.